Download the upgrade file for the BN here. File name “SYS.A3.B10.XXX.0.9xx.0xx.00.tbn” (presently 989.037 is the current release). Please Note: The name of the .tbn file in this article may be different from the name within the download link.
-
Power the BN and connect the laptop to the Management Gigabit Ethernet port of the BN.
-
Assign a static IP address of 192.168.10.x/24 to the laptop.
-
Type 192.168.10.2 into a web browser to access the BN’s web interface.
-
For the username and password, enter “admin” and “admin123”, respectively. This will bring up the BN’s web interface.
-
From the “Upgrade” section of the web UI, click on “CHOOSE FILE” and browse to select the upgrade file for the BN (“SYS.A3.B10.XXX.0.9xx.0xx.00.tbn”)
-
Click “CONFIRM UPGRADE”. A status window will then show the progress.
-
Upon completion, click “Go to REBOOT”. After ~5 minutes, the device will be upgraded, and the web UI will reappear.
-
Download the upgrade file for the RN here. File name “SYS.A3.R10.XXX.0.9xx.0xx.00.tbn” (presently 989.037 is the current release). Please Note: The name of the .tbn file in this article may be different from the name within the download link.
-
Power the RN and connect the laptop to the RN’s PoE.
-
Assign a static IP address of 192.168.10.x/24 to the laptop.
-
Type 192.168.10.2 into a web browser to access the RN’s web interface.
-
For the username and password, enter “admin” and “admin123”, respectively. This will bring up the RN’s web interface.
-
From the “Upgrade” section of the web UI, click on “CHOOSE FILE” and browse to select the upgrade file for the RN (“SYS.A3.R10.XXX.0.9xx.0xx.00.tbn”).
-
Click “CONFIRM UPGRADE”. A status window will then show the progress.
-
Upon completion, click “Go to REBOOT”. After ~5 minutes, the device will be upgraded, and the web UI will reappear.